01
PP pleated cartridges
Gradient-density microfiber media with high pleated area for compatible critical liquid duties.
PP PleatedLiquid and air filtration
Manufactured by Sri Bharathi for liquid and air filtration, our range includes pleated, PTFE membrane, spun-bonded, wound, stainless-steel and dust-collection cartridges.
From Ankleshwar, Gujarat, Sri Bharathi supplies industrial buyers across India with standard and application-specific cartridge grades, sizes and end configurations.


Portfolio
01
Gradient-density microfiber media with high pleated area for compatible critical liquid duties.
PP Pleated02
Hydrophobic expanded-PTFE membrane for sterile venting, process gases and compatible aggressive liquids.
PTFE Membrane03
One-piece 100% polypropylene depth media with progressive outside-to-inside retention.
Spun Bonded04
Controlled yarn winding around PP or stainless-steel cores for robust depth filtration.
Wound Cartridges05
Reusable mesh, sintered or fibre-metal elements for high-temperature and differential-pressure duties.
Stainless Steel06
Pleated polyester media with application-specific coatings for industrial air filtration.
Dust CollectionSelection framework
Nominal and absolute ratings describe different performance claims and require a stated test method. Pleated surface area, depth gradient, fibre diameter, pore stability and the incoming particle distribution all influence real separation performance.
Confirm cartridge length, outside and inside diameter, end connection, gasket or O-ring material, flow direction, housing fit, operating temperature, differential pressure and sanitisation or cleaning method. Fluid compatibility must include every wetted component—not only the filter medium.
Questions engineers ask
Pleated cartridges use folded media for high area and are often selected for defined polishing duties. Spun and wound depth cartridges distribute solids through a thicker matrix and can suit higher dirt loads.
Double open end describes a cartridge open at both ends, normally sealed in the housing using separate gaskets or knife-edge arrangements.
No. The claim must include the efficiency definition and test method. A nominal label without test context is not equivalent to an absolute-rated element.
Consider it where temperature, chemical exposure, differential pressure, backwashing or reuse exceeds the practical limits of polymeric media—subject to metallurgy and pore validation.
Application support
Share housing geometry, current end configuration, seal material, fluid, temperature, flow, differential pressure, solids load and target retention.
Product documents
Explore the full range in our Filters Catalogue and Product Offerings overview, alongside technical presentations.